MySQL 1060

This error occurs when a duplicate field name is found in a table. It is a MySQL 1060 error and the literal message is "Duplicate column name '%s'".

How It Affects Your App

MySQL 1060 ER_DUP_FIELDNAME has a significant impact on an application. It indicates that the same column name has been used multiple times in a table. This can lead to confusion and errors when trying to access the data in the table. It can also cause issues when trying to add or modify data in the table. In addition, it can lead to data integrity issues as the same column name can be used to store different data types. This can lead to data corruption and incorrect results.

How To Fix

1. Check the error log for the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW GLOBAL VARIABLES LIKE 'log_error';
2. Check the error log file for the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW GLOBAL VARIABLES LIKE 'log_error_file';
3. Check the syntax of the query causing the MySQL 1060 error. This can be done by running the following command:
mysql> EXPLAIN EXTENDED SELECT * FROM table_name;
4. Check the privileges of the user causing the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW GRANTS FOR 'username'@'hostname';
5. Check the table structure for the table causing the MySQL 1060 error. This can be done by running the following command:
mysql> DESCRIBE table_name;
6. Check the indexes of the table causing the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW INDEX FROM table_name;
7. Check the foreign keys of the table causing the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW CREATE TABLE table_name;
8. Check the database engine of the table causing the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW TABLE STATUS LIKE 'table_name';
9. Check the server configuration for the MySQL 1060 error. This can be done by running the following command:
mysql> SHOW GLOBAL VARIABLES;
10. Finally, it is recommended to use an automated database observability tool to monitor and fix the MySQL 1060 in question. This tool can provide real-time insights into the performance and health of the database, as well as alerting when an issue arises. It can also provide detailed analysis of the root cause of the issue, allowing for quick and efficient resolution.

Metis takes your database to the next level

The only way to

your database

Never worry about your
database again!

Start using Metis and get your database guardrails set up in minutes